Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	43
Date	08/12/14
Start Time	10:47:35
Diameter Midpoint
 10.9	504.846
 11.3	40613.4
 11.8	230347
 12.2	263485
 12.6	302090
 13.1	356028
 13.6	400682
 14.1	444508
 14.6	492230
 15.1	553547
 15.7	604578
 16.3	654377
 16.8	702930
 17.5	750153
 18.1	793609
 18.8	828365
 19.5	861124
 20.2	885870
 20.9	892851
 21.7	900113
 22.5	899657
 23.3	886029
 24.1	863870
 25.0	836696
 25.9	798135
 26.9	752024
 27.9	690081
 28.9	625188
 30.0	554637
 31.1	482472
 32.2	411653
 33.4	340404
 34.6	278599
 35.9	223998
 37.2	178892
 38.5	136805
 40.0	101888
 41.4	71188.5
 42.9	48496.1
 44.5	32111.4
 46.1	21106.6
 47.8	13679
 49.6	8509.35
 51.4	5430.62
 53.3	3769.82
 55.2	2383.29
 57.3	1672.45
 59.4	1152.5
 61.5	852.149
 63.8	741.679
 66.1	528.044
 68.5	434.083
 71.0	341.315
 73.7	297.498
 76.4	233.033
 79.1	217.145
 82.0	163.503
 85.1	156.601
 88.2	155.646
 91.4	123.219
 94.7	109.73
 98.2	118.078
101.8	78.15
105.5	110.455
109.4	79.1479
113.4	88.2937
117.6	84.7075
121.9	90.1116
126.3	77.1461
131.0	72.2213
135.8	64.6723
140.7	58.9392
145.9	59.1077
151.2	33.364
156.8	49.1139
162.5	48.2804
168.5	44.2301
174.7	54.2224
181.1	53.8957
187.7	39.0609
194.6	55.8905
201.7	45.8677
209.1	34.4629
216.7	45.2837
224.7	40.2125
232.9	40.3329
241.4	45.0724
250.3	24.7109
259.5	34.9739
269.0	18.5235
278.8	25.7316
289.0	17.1181
299.6	19.7734
310.6	17.793
322.0	13.7898
333.8	1.84664
346.0	19.2373
358.7	7.34712
371.8	4.41826
385.4	6.61471
399.5	3.28949
414.2	3.74238
429.4	4.72686
445.1	8.60178
461.4	4.93187
478.3	10.926
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1715
High Voltage	9863.18
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	21.3425
Mean(nm)	22.2676
Geo. Mean(nm)	21.3155
Mode(nm)	21.6739
Geo. Std. Dev.	1.34201
Total Concentration(#/cm)	2.02347e+007
Comment	